Siemens simatic et 200s Operating Instructions Manual page 131

Positioning
Hide thumbs Also See for simatic et 200s:
Table of Contents

Advertisement

Parameters
Switch-off
Switch-off difference
Switchover difference
Acceleration T
in ms
Deceleration T
in ms
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
Meaning
Use this parameter to determine the
course of the voltage after the switch-off
point. It is only effective in the relative and
absolute positioning modes.
Directly: The voltage is set directly to 0 V
at switch-off point.
Ramp: As of switch-off point, voltage is
reduced to 0 V using the ramp.
Defines the distance from the destination
at which the drive is slowed down from
creep feed to 0.
If the switch-off difference ≥ the
switchover difference, there is no
switchover point. There is no deceleration
from rapid to creep feed, and instead the
response is executed directly at the
switch-off point.
You can change the switch-off difference
with JOB 3.
Defines the distance from the destination
at which the drive is slowed down from
rapid feed to creep feed.
Time required for a change in voltage via
acc
a ramp from 0 V to10 V.
At 0 ms acceleration is without a ramp.
Time required for a change in voltage via
dec
a ramp from 10 V to 0 V.
At 0 ms deceleration is without a ramp.
1PosInc/Analog
4.6 Functions of the 1PosInc/Analog
Value range
Default setting
Directly
Directly
Ramp
0 - 65 535
100
0 - 65 535
1000
0 - 65535
10000
0 - 65535
10000
131