Absolute Positioning (Mode 5) - Siemens simatic et 200s Operating Instructions Manual

Positioning
Hide thumbs Also See for simatic et 200s:
Table of Contents

Advertisement

4.6.7

Absolute Positioning (MODE 5)

Definition
Using absolute positioning, the 1PosInc/Analog moves the drive towards absolute
destinations. To do this, the axis must be synchronized.
Supply the control interface with the destination, and start MODE 5 with the necessary
directional enable (DIR_M, DIR_P). The 1PosInc/Analog moves the drive towards the
destination with the set voltage for rapid feed. At the switchover point, the 1PosInc/Analog
decelerates from rapid to creep feed. At the switch-off point, the 1PosInc/Analog completes
the run either directly or via the ramp depending on the parameter assignment.
If you start during a current run, the 1PosInc/Analog executes any required change in
direction using deceleration or acceleration.
Linear axis
The 1PosInc/Analog determines the direction the destination is to be approached from. You
must set the necessary directional enable (DIR_M, DIR_P) to start. You can also set both
enables.
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
1PosInc/Analog
4.6 Functions of the 1PosInc/Analog
145

Advertisement

Table of Contents
loading

Table of Contents