6.6.8

Canceling JOB Processing (JOB 0)

Definition
If you activate JOB 0, the 1PosSSI/Analog responds as follows:
● It cancels the current JOB 9 (reference signal evaluation)
● It cancels the current JOB 10 (latch function)
● It sets a pending JOB_ERR = 0.
You can activate JOB 0 whatever the state of the axis.
Effect on the MODEs
MODEs are not affected by JOB 0.
Control Signals: Canceling JOB processing
Address
Byte 4
Feedback Signals: Canceling JOB processing
Address
Byte 4
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
Assignment
Bits 4.7 to 4.4 :
Bit
7
6
0
0
Bit 0: JOB_REQ
Assignment
Bit 1: JOB_ERR
Bit 0: JOB_ACK
6.6 Functions of the 1PosSSI/Analog
5
4
JOB 0 = Cancel JOB processing
0
0