1PosInc/Analog
4.10 Technical Specifications for the 1PosInc/Analog
Technical Data of the 1PosInc/Analog
Suppression of interference, limits of error
Operational limit (in the entire temperature range,
with reference to the output range)
Basic error limit (operational limit at 25°C with
reference to output range)
Temperature error (with reference to the output
range)
Linearity error (with reference to the output range)
Repeatability (in steady state at 25°C with
reference to output range)
Output ripple (with reference to output range,
bandwidth 0 to 50 kHz)
Data for selecting an actuator
Output range (rated value)
Load resistance
Destruction limit against voltages/currents applied
from outside
Connection of actuators
Encoder signals
Level
Length of cable
Status, Diagnostics
Change in actual value (up)
Change in actual value (down)
Status display positioning in operation
Status display DI0 (minus hardware limit switch)
Status display DI1 (plus hardware limit switch)
Status display DI2 (reducing cam)
Group error on the 1PosInc/Analog
Diagnostic information
186
For capacitive load
Short-circuit protection
Short-circuit current
Voltage at the outputs to M
Current
2-conductor connection
Terminating resistance
Differential input voltage
Max. frequency
Shielded
± 0.4 %
± 0.2 %
± 0.01 %/K
± 0.02 %
± 0.05 %
± 0.02 %
±10 V
Min. 1.0 kΩ
Max. 1 µF
Yes
Approx. 25 mA
Max. 15 V continuous; 75 V for max. 1 s
ANA
(pulse duty factor 1/20)
Max. DC 50 mA
No compensation for surge impedance
To RS 422
330 Ω
Min. 1 V
500 kHz
Max. 50 m
UP LED (green)
DN LED (green)
LED POS (green)
LED 9 (green)
LED 13 (green)
LED 14 (green)
SF LED (red)
Yes