1PosSSI/Digital
5.6 Functions of the 1PosSSI/Digital
5.6.5

Inching (MODE 1)

Definition
You use inching mode to control the drive directly in a particular direction using the DIR_M or
DIR_P control bits.
If you start MODE 1, the 1PosSSI/Digital moves the drive at the preset speed
(SPEED control bit) in the specified direction (control bit DIR_M or DIR_P).
You stop the drive by setting the control bits DIR_P=0 and DIR_M=0.
A change of direction is executed after the time T
You can also activate inching on an unsynchronized axis (feedback bit SYNC = 0) or when
there is a pending encoder error (feedback bit ERR_ENCODER = 1) or without an encoder
connected.
START
DIR_P
DIR_M
SPEED
POS_ACK
POS_DONE
POS_ERR
SYNC
Rapid feed
Creep feed
Figure 5-9
208
Execution of Inching
elapses.