Slot 4 Menu 0: Ethernet Status And Monitoring; Slot 4 Menu 2: Ethernet Configuration - Emerson Unidrive M702 User Manual

Universal variable speed ac drive for induction and permanent magnetmotors
Hide thumbs Also See for Unidrive M702:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
11.21.1

Slot 4 Menu 0: Ethernet status and monitoring

Parameter
24.001
Module ID
24.002
Software Version
24.003
Hardware Version
24.004
Serial Number LS
24.005
Serial Number MS
24.006
Status
24.007
Reset
24.008
Default
24.009
Active Alarm Bits
24.010
Active IP Address
RW
Read / Write
RO
Read only
ND
No default value
NC
Not copied
IP
IP address
Mac
Mac address
11.21.2

Slot 4 Menu 2: Ethernet configuration

Parameter
4.02.003
Network Status
4.02.004
Network Message Count
4.02.005
DHCP Enable
4.02.006
IP Address
4.02.007
Subnet Mask
4.02.008
Default Gateway
4.02.009
Primary DNS
4.02.010
Secondary DNS
4.02.011
MAC Address
4.02.020
Priority Protocol
4.02.021
Web Server Enable
4.02.022
Web Server Port
4.02.024
Ethernet MTU
4.02.025
Gateway Mode
4.02.030
VLAN Enable
4.02.031
VLAN ID
4.02.035
Non cyclic enable
4.02.036
Non cyclic base parameter
RW
Read / Write
RO
Read only
ND
No default value
NC
Not copied
IP
IP address
Mac
Mac address
218
Electrical
Getting
Basic
installation
started
parameters
OL
RFC-A
0 to 65535
00.00.00.00 to 99.99.99.99
0.00 to 99.99
00000000 to 99999999
0 to 99999999
Bootldr-Update (-2), Bootldr-Idle (-1),
Initializing (0), OK (1), Config (2), Error (3)
Off (0) or On (1)
Off (0) or On (1)
0000000000000000 to 1111111111111111
128.0.0.0 to 127.255.255.255
Num
Number parameter
Bit
PT
Protected parameter
RA
Date
Date parameter
Time
OL
Initializing (0), Links Down (1),
DHCP In Progress (2), No Address (3),
Ready (4), Active (5)
Off (0) or On (1)
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
00:00:00:00:00:00 to FF:FF:FF:FF:FF:FF
None (0), Modbus TCP (1), EtherNet/IP (2)
Off (0) or On (1)
158 to 1500 Bytes
Switch (0), Gateway (1),
Strict Gateway (2)
Off (0) or On (1)
Off (0) or On (1)
0.00.000 to 0.59.999
Num
Number parameter
Bit
PT
Protected parameter
RA
Date
Date parameter
Time
Running
NV Media Card
Optimization
the motor
Operation
Range
RFC-S
OL
Bit parameter
Txt
Text string
Rating dependent
US
User save
Time parameter
SMP
Slot,menu,parameter
Range
RFC-A
RFC-S
OL
0 to 65535
0 to 65535
0 to 255
Bit parameter
Txt
Text string
Rating dependent
US
User save
Time parameter
SMP
Slot,menu,parameter
Onboard
Advanced
Technical
PLC
parameters
data
Default
RFC-A
RFC-S
RO
Num
RO
Num
RO
Num
RO
Num
RO
Num
RO
Off (0)
RW
Off (0)
RW
0000000000000000
RO
0.0.0.0
RO
Bin
Binary parameter
PS
Power-down save
Chr
Character parameter
Default
RFC-A
RFC-S
RO
RO
On (1)
RW
192.168.001.100
RW
255.255.255.000
RW
192.168.1.254
RW
0.0.0.0
RW
0.0.0.0
RW
RO
0
RW
On (1)
RW
80
RW
1500 Bytes
RW
Switch (0)
RW
Off (0)
RW
0
RW
Off (0)
RW
0.00.000
RW SMP
Bin
Binary parameter
PS
Power-down save
Chr
Character parameter
Unidrive M702 User Guide
UL listing
Diagnostics
information
Type
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
Txt
ND
NC
PT
Bit
NC
Bit
NC
Bin
NC
IP
NC
PT
FI
Filtered
DE
Destination
Ver
Version number
Type
Txt
ND NC
PT
Num ND NC
PT
Num
US
IP
US
IP
US
IP
US
IP
US
IP
US
Mac
ND NC
PT
Txt
US
Bit
US
Num
US
Num
US
Txt
US
Bit
US
Num
US
Bit
US
US
FI
Filtered
DE
Destination
Ver
Version number
Issue Number: 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents