Encoder Simulation Output Set-Up - Emerson Unidrive M702 User Manual

Universal variable speed ac drive for induction and permanent magnetmotors
Hide thumbs Also See for Unidrive M702:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Absolute EnDat communication only encoder or BiSS encoder
Device Type (03.138)
Auto-configuration Select (03.141)
Comms Baud Rate (03.137)
Error Detection Level (03.140)
Absolute SSI communications only encoder
Device Type (03.138)
SSI Binary Mode (03.148)
Rotary Turns Bits (03.133)
Comms Bits (03.135)
Comms Baud Rate (03.137)
Error Detection Level (03.140)
7.5

Encoder Simulation Output Set-up

The drive supports three modes of encoder simulation output.
Hardware mode - Incremental signals (AB, FD, FR)
Software mode - Incremental signals (AB, FD, FR)
Software mode - Absolute SSI data
The availability of the encoder simulation output on the 15-way D-type on the drive is dependent on the type of feedback device connected to the P1
position interface. See Table 4-27 on page 81 for more information on the availability of the encoder simulation output. The status of the encoder
simulation output can be seen in Encoder Simulation Status (03.086) as follows:
None (0)
The encoder simulation output is not enabled or is not available
Full (1)
Full encoder simulation with marker output is available
No Marker (2) Encoder simulation without marker output is available
This section shows the parameter settings which must be made to use the encoder simulation output on the drive. For more information on the
parameters listed here please refer to the Parameter Reference Guide.
7.5.1
Hardware mode - Incremental signals (AB, FD, or FR)
Hardware mode provides incremental signals derived via hardware from the P1 position feedback interface on the drive, with negligible delay. The
supported incremental output signals are AB, FD and FR. Hardware mode only produces an output when the input device connected to the P1
position interface is AB, FD, FR, SC, SC Hiperface, SC EnDat or SC SSI type devices. It should be noted that with a SINCOS source device the
output is based on the zero crossings of the sine wave inputs and does not include interpolation.
Unidrive M702 User Guide
Issue Number: 3
Electrical
Getting
Basic
installation
started
parameters
the motor
EnDat (4) for an EnDat communications only encoder
BiSS (6) for a BiSS communication only encoder
Auto-configuration is enabled at default and automatically sets up the following parameters:
Rotary Turns Bits (03.133)
Comms Bits (03.135)
These parameters can be entered manually when Pr 03.141 is set to Disabled (0).
100 k, 200 k, 300 k, 400 k, 500 k, 1 M, 1.5 M, 2 M, 4 M
Bit
3
2
1
0
1
x
x
x
Disable trips Encoder 4 to Encoder 7
SSI (5) for a SSI communications only encoder
Off (0) = Gray Code
On (1) = Binary Mode
Set to the number of turns bits for the encoder (this is usually 12 bits for a multi-turn SSI encoder)
Total number of bits of position information for the encoder (this is usually 25 bits for a multi-turn SSI
encoder)
100 k, 200 k, 300 k, 400 k, 500 k, 1 M, 1.5 M, 2 M, 4 M
Bit
3
2
1
0
x
1
x
x
Enable SSI power supply alarm bit monitor
1
x
x
x
Disable trips Encoder 4 to Encoder 7
Running
NV Media Card
Optimization
Operation
Description
Description
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
UL listing
information
115