Recommended cable
It is recommended that a minimum specification of CAT5e is used in new
installations. If the existing cabling is used this may limit the maximum
data rate depending on the cable ratings. In noisy environments the use
of STP cable will offer additional noise immunity.
Maximum network lengths
The main restriction imposed on the Ethernet cabling is the length of a
single segment of the cable, for Copper - UTP/STP CAT 5 cable type,
maximum trunk cable length should be limited to 100 m. If distances
greater than this are required it may be possible to extend the network
with additional switches.
Ethernet set-up parameters
The following section covers the minimum number of parameters
required to be set to establish an Ethernet communication.
Table 5-9 Key to parameter table coding
RW
Read / Write
RO
Read only
Num
Number parameter
Bit
Bit parameter
Txt
Text string
Bin
Binary parameter
FI
Filtered
IP
IP Address
Date
Date parameter
4.00.007
Reset
{24.007}
RW
Bit
Off (0) or On (1)
Changes to the Ethernet set-up parameters will not take effect until a
Reset (4.00.007) has been performed.
4.00.010
Active IP Address
RO
IP
000.000.000.000 to
255.255.255.255
This parameter displays the Active IP Address. The Active IP Address
can also be viewed in Pr 00.037.
4.02.005
DHCP Enable
RW
Bit
Off (0) or On (1)
If DHCP Enable (4.02.005) is set to On (1), the IP address is acquired
from the DHCP server and written to IP Address (4.02.006).
NOTE
When using manual / static IP address configuration, ensure Subnet
Mask (4.02.007) and Default Gateway (4.02.008) should also be set
manually.
4.02.006
IP Address
RW
IP
000.000.000.000 to
255.255.255.255
Unidrive M702 User Guide
Issue Number: 3
Electrical
Getting
Basic
installation
started
parameters
the motor
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependant
US
User save
PS
Power-down save
DE
Destination
Mac
Mac Address
Time
Time parameter
US
Off (0)
US
US
On (1)
US
192.168.001.100
Running
NV Media Card
Optimization
Operation
This parameter controls and displays the IP address of the drive. If
DHCP Enable (4.02.005) is set to On (1) this parameter will become
read-only.
4.02.007
Subnet Mask
RW
IP
000.000.000.000 to
255.255.255.255
This parameter controls and displays the Subnet Mask (4.02.007) of the
drive.
4.02.008
Default Gateway
RW
IP
000.000.000.000 to
255.255.255.255
This parameter controls and displays the Default Gateway (4.02.008) of
the drive.
PC Tools support
The discovery protocol feature, which is supported by the Unidrive M PC
tools, is able to discover the drives that are connected to a PC,
independent of above parameter settings.
Onboard
Advanced
Technical
Diagnostics
PLC
parameters
data
255.255.255.000
192.168.1.254
UL listing
information
US
US
95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents