Figure 13-11 Aps Redundant Frame Assembly - Cisco BPX 8620 Installation And Configuration Manual

Hide thumbs Also See for BPX 8620:
Table of Contents

Advertisement

Installation of APS Redundant Frame Assembly and Back Cards
To install APS Redundant Frame Assembly and back cards, use the following procedure:
If not already in place in the APS Redundant Frame Assembly, slide the two APS back cards into the
Step 1
APS Redundant Frame Assembly.
Warning
Nylon standoffs on the APS Redundant Frame Assembly must be in place to prevent shorting
against -48 VDC pins and ground pins on the BPX Midplane.
Verify that nylon standoffs are securely installed on APS Redundant Frame Assembly
Step 2
(see Figure 13-11).
Step 3
Carefully slide APS Redundancy Frame Assembly and APS cards into selected side-by-side slots at the
back of the BPX shelf (see Figure 13-12). Slide the APS Redundancy Frame Assembly and cards into
the BPX shelf until snug against the BPX midplane (see Figure 13-13).
Going back and forth between the screws, gradually tighten retaining screws at top and bottom of the
Step 4
APS back cards until all are secure.

Figure 13-11 APS Redundant Frame Assembly

Cisco BPX 8600 Series Installation and Configuration
13-14
Nylon standoffs
APS redundant
backplane
connector
Nylon standoffs
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 13
Installing the BPX Switch Cards