Fan Power Fuses
Fan Power Fuses
Fan fuses are located on the backplane of the BPX switch to protect against catastrophic backplane
damage in the event of a shorted fan cable. Backplane fuses should rarely, if ever, need replacement. The
fuses are designated F1 through F3, corresponding to fans 1 through 3.
For instructions on replacement of these fuses, see Chapter 29, "Replacing Parts." Contact Cisco
Caution
Customer Service for assistance regarding their replacement.
For continued protection against risk of fire, replace only with the same type and rating of fuse.
Caution
Replace fuses only after all power to the BPX switch has been turned off.
Cisco BPX 8600 Series Installation and Configuration
11-12
Chapter 11
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Installing the AC Shelf