Parts Checklist - Cisco BPX 8620 Installation And Configuration Manual

Hide thumbs Also See for BPX 8620:
Table of Contents

Advertisement

Chapter 7
Preliminary Steps Before Installing

Parts Checklist

Parts Checklist
Before proceeding, go through this parts checklist to verify that all the parts you ordered are present, and
that they are all in good condition. If there is anything missing or damaged, report it to your Cisco Order
Administration representative.
Plug-in cards may be shipped installed or under separate cover. The exact number of cards will vary from
site to site, depending on the selected configuration.
The BPX switch is shipped with all unused slots covered by backplane inserts that prevent radio
frequency emissions from the equipment. The unit must not be operated with any unused slots left
uncovered.
Refer to this list to check the number and type of cards shipped against the number and type of card you
ordered. Check that:
If a DC version, it has the correct number of Power Entry modules.
If an AC version, it has the correct number of power supplies (1 or 2).
For nonredundant configuration, there should be one Broadband Controller Card. This can be a
BCC-4v, BCC-3-32M, BCC-3-64M, or a BCC-32 depending on system configuration
For a nonredundant configuration, there should be one Broadband Controller back card. For a
BCC-4V or BCC-3-32M, or BCC-3-64M front card, a BCC-3-BC back card must be used. For a
BCC-32 front card, a BCC15-BC back card must be used.
For a redundant configuration, there should be two Broadband Controller Cards. These can be two
BCC-4Vs, BCC-3-32Ms, or BCC-64Ms, or two BCC-32s.
For a redundant configuration, there should be two Broadband Controller back cards. For BCC-4V,
BCC-3-32M, or BCC-3-64M front cards, these must be BCC-3-BC back cards. For BCC-32 front
cards, these must be BCC15-BC back cards.
One ASM card.
One LM-ASM card.
Correct number of BXM cards.
Correct number of BNI cards.
Correct number of BME cards.
One line module back card for each BXM, as applicable (such as, BPX-T3/E3-BC, MMF-155-4,
SMF-155-4, SMFLR-155-4, MMF-155-8, SMF-155-8, SMFLR-155-8, SMF-622, SMFLR-622,
SMF-622-2, or SMFLR-622-2),
or STM-1 back card,
or SONET APS back cards (such as, SMF-155-4R, SMF-155-8R, SMF-622-1R, SMF-622-2R,
SMF-LF-155-4R, SMF-LF-155-8R, SMF-LF-622-1R, and SMF-LR-622-2R,
One line module back card, SMF-622-2 for each BME.
Cisco BPX 8600 Series Installation and Configuration
7-2
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bpx 8650Bpx 8680Bpx 8680-ip

Table of Contents