Fault Management And Statistics; Port Mode - Cisco BPX 8620 Installation And Configuration Manual

Hide thumbs Also See for BPX 8620:
Table of Contents

Advertisement

Chapter 5
BXM Card Sets: T3/E3, 155, and 622

Fault Management and Statistics

This section describes the specifications used for fault management and statistics.

Port Mode

Compliant to Bellcore GR-253-CORE
Alarms
Performance Monitoring
Statistics
OAM
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Loss Of Signal (LOS)
Loss Of Pointer (LOP)
Loss Of Frame (LOF)
Loss Of Cell Delineation (LOC)
Alarm Indication Signal (AIS)
Remote Defect Indication (RDI)
Alarm Integration Up/down Count
Performance monitoring provided for Line, Section, and Path
Bit Interleaved Parity (BIP) error detection
Far End Block Error (FEBE) count
Unavailable Seconds (UAS)
Errored Seconds (ES)
Severely Errored Seconds (SES)
Header Error Checksum (HCS) monitoring
ATM statistics collected on a per VC basis
The number of statistics that are collected on a VC depends on the Channel Stats Level, which is
configured using the cnfcdparm command.
ATM statistics collected on a per physical interface basis
ATM statistics collected on a per Virtual Interface basis
Loopback support
Generation and detection of AIS and RDI OAM cells
Termination and processing of OAM cells