Non-Multiplex Receivers With Ten Channels; Menu Monitor; Menu: Test Run; Main Menu Timer A - Multiplex Royal SX 9 Instructions Manual

Table of Contents

Advertisement

17.2.2.
Non-MULTIPLEX receivers with ten
channels
Other makes of ten-channel receiver continue to use
the "standard" signal format. If such receivers are to
work properly in conjunction with the ROYAL SX 16,
you must not assign functions to the eleventh and
twelfth servos.

Menu Monitor

17.3.
The Servo Monitor acts as a substitute for a receiving
system with servos connected to it, and enables you
to detect errors and check the function / operation of
speed controllers, gyro systems, speed governors, ... .
Two types of screen display are available: graphic,
with a display of output signals in bar-chart form, and
numerical, with all values stated as percentages. You
can toggle between the two displays using the UP /
DOWN buttons (▲ / ▼); alternatively you can switch
between them using one of the two 3-D digi-adjusters:
Bar graph display

Menu: Test run

17.4.
Automatic servo operation, which can be used for test
or demonstration purposes, or as an "electronic" aid
when range-checking the system:
Servo test with rudder active
As soon as you select a transmitter control, the trans-
mitter generates a steady signal which moves the
servo from one end-point of the control to the other
and back. All servos which are operated by this con-
trol - either directly or via a mixer - start running.
You can halt the servo test in either of two ways:
 Press the REV/CLR button: Control appears
 Select no transmitter control: - - - - - - -
The transit speed can be set to any value within the
range OFF via 0.1s to 6.0s (seconds).
!
Caution: Servo test using the Throttle control!
To ensure that no danger or damage occurs as a re-
sult of the motor bursting into life, use this procedure:
a. Set the transit Time to OFF.
b. Select the desired transmitter control.
c. Set the transit time to the desired value.
Numerical display
Servo test halted
Main menu Timer
18.
The main menu Timer is opened by pressing this but-
ton:
A
The ROYAL SX has five timers; four of them are
found in the main menu ¥ Timer:
¥Timer
¨Exit
Model
µSlot
´Sum
¶Interval
The fifth timer records the transmitter's operating time,
and is only displayed in Status display 4 ( 10.8.4.).
Slot, Sum and Interval timers:
18.1.
display and reset
The timers Slot, Sum and Interval are shown in
Status display 3, but only if a switch has been as-
signed to them:
Counting direction
In this example no switches have been assigned to the Sum
and Interval timers.
This Status display includes the direction of counting
and the assigned switch as well as the current timer
status.
How to locate Status display 3:
If one of the other Status displays is already on-
screen, you can leaf through all four Status displays
using the ▲ or ▼ buttons until you arrive at the Timer
summary. If you now call up a menu, repeatedly
pressing any main menu button takes you to a Status
display. From this point on you can leaf through the
other displays.
Resetting the timers:
Press the REV/CLR button, and all the timers will be
reset to the set alarm time.
Manual
A
....
18.2.
....
18.3.
....
18.4.
18.5.
....
Assigned switch
Slot
Sum
Interval
81

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Royal sx 16