Connecting an Attendant Console

553-3021-209
Standard 3.00
Chapter 17 — Connecting the telephones
Procedure 33
Connecting an off-premise telephone
1
Install the NTAK92AA Off-Premise Protection Module on the wall
using four #10 1/2 in (minimum) screws.
2
Connect a #6 AWG (#40 Metric Wire Gauge) from the grounding
lug at the bottom of the NTAK92AA Off-Premise Protection
Module to an earth ground. Refer to Figure 68 on page 237.
Note: In the UK, use a 2 mm
#6 AWG (16 mm
If connecting to a message waiting line card, unseat the card from its
assigned slot before continuing with the next step.
3
Connect two NTAK9204 cables (one from connector J1 and one
from connector J2) from the protection module to the
cross-connect terminal.
Terminate the cables as shown in Figure 65 on page 231.
4
Cross-connect the J1 cable to the Tip and Ring connections
coming from the line card.
Table 52 on page 242 provides the default DN assignments.
5
Cross-connect the J2 cable to the off-premise telephone.
6
Install the regulatory label provided with the Off-Premise
Protection Module on the inside right-hand wall of the chassis.
7
Install the line card in its assigned position.
Now, you can activate the telephone, as described on page 244.
—————————— End of Procedure ——————————
Procedure 34
Connecting Attendant Console
1
Locate the Attendant Console terminations at the cross-connect
terminal.
2
Locate the line card terminations at the cross-connect terminal.
April 2000
2
(#6 AWG) ground lug. In Europe, use a
2
) ground lug.
WARNING