Chapter 8 — Bracing the Option 11C Mini against earthquakes
3
Determine where to place the fasteners
Refer to Figures 19 through 21 if you need help with where to place the
fasteners on the backboard. In each figure, the minimum (2 ft by 6 ft)
and maximum (4 ft by 8 ft) sizes of the backboard are used as
examples.
• Figure 19 on page 110 provides the fastener locations for
• Figure 20 on page 111 provides the fastener locations for
• Figure 21 on page 112 provides the fastener locations for
wood and metal stud walls with the minimum acceptable stud
spacing of 16 in. (400 mm).
wood and metal stud walls with the maximum acceptable stud
spacing of 24 in. (600 mm).
concrete and masonry walls.
Option 11C Mini
Page 109 of 332
Planning and Installation Guide