Conflicts with Flexible Feature Codes

553-3021-209
Standard 3.00
Appendix B – Changing preprogrammed data
If the preprogrammed Flexible Feature Codes (FFC) conflict with the
programming required for the Option 11C Mini system, remove the data from
the system using LD 57.
LD 57
To change one or more access codes, enter the following commands:
REQ
CHG, END
TYPE
FFC
CUST
0-31
FFCT
YES,(NO)
CODE
aaaa
AAAA
xx
CODE
<CR>
REQ
END
To remove one access code, enter the following commands:
REQ
OUT
TYPE
FFC
CUST
0-31
FFCT
YES,(NO)
ALL
NO
CODE
aaaa
AAAA
xx
CODE
<CR>
REQ
END
April 2000
Change or end
FFC = Flexible feature codes
Customer Number
FFC Confirmation tone
Enter access code prompt (aaaa)
Enter the new access code prompt
(AAAA)
Return to REQ
End program
Action request
FFC = Flexible feature codes
Customer Number
FFC Confirmation tone
Remove specific access code
Enter access code prompt (aaaa)
Enter the new access code prompt
(AAAA)
Return to REQ
End program