Page 320 of 332

Removing numbering plan conflicts

Conflicts with Meridian Mail Mini data

553-3021-209
Standard 3.00
Appendix B – Changing preprogrammed data
Example:
The first number in the numbering plan is 2200. For the first number in the
numbering plan to be 2300, and the first line card is in slot 6, perform the
following calculation:
1
Locate the first line card. Subtract 1 from the number of the card slot that
it is in.
6 - 1 = 5
2
Multiply the number from step 1 by 16:
5 X 16 = 80
3
Subtract this number from the first number in the numbering plan:
2300 - 80 = 2220
4
Enter this value in response to the "FIRST NUMBER (2200)?" prompt
on the administration telephone:
FIRST NUMBER (2000)? 2220
This section contains methods for removing any numbering plan conflicts
that occur.
Manufacturers and distributors ship the Option 11C Mini system with data
already programmed to support Meridian Mail Mini. The Meridian Mail Mini
preprogrammed data can cause problems in the following situations:
there is a numbering plan conflict with preprogrammed Meridian Mail
Mini data and the programming required for another feature
another circuit card requires card slot 10
April 2000