2. The meter reading must be within specification.
Secondary Winding
1. Connect the red tester lead to the high tension lead
(with the plug cap removed); then connect the black
tester lead to either primary terminal.
2. The meter reading must be within specification.
NOTE: If the meter does not show as specified,
replace ignition coil.
Spark Plug Cap
1. Connect the red tester lead to one end of the cap;
then connect the black tester lead to the other end of
the cap.
2. The meter reading must be within specification.
NOTE: If the meter does not show as specified,
replace the spark plug cap.
VOLTAGE
Primary Coil
1. Set the meter selector to the DC Voltage position;
then disconnect the two wires from the coil.
NOTE: The coil is located to the right of the
engine and may be accessed from behind the
right-side seat with the cargo box raised.
2. Connect the red tester lead to the orange wire and the
black tester lead to the blue/white wire.
80
3. Turn the ignition switch to the ON position. The
meter must show battery voltage.
Manifold Absolute
Pressure (MAP) Sensor
 NOTE: Preliminary checks may be performed on
this component using the diagnostic mode on the
LCD gauge (see EFI Diagnostic System in this sec-
tion).
PR278A
1. Disconnect the MAP connector from the pressure sensor
located on the throttle body.
2. Select DC Voltage on the tester and turn the ignition
switch to the ON position.
3. Connect the black tester lead to the black/green wire and
the red tester lead to the orange/blue wire. The meter
should read 4.5-5.5 DC volts. If the meter does not read
as specified, check the ECM connector or wiring.
4. Connect the MAP to the harness; then using MaxiClips,
connect the red tester lead to the brown/white wire and
the black tester lead to the black/green wire. With the
engine running at idle speed, the meter should read
approximately 1.5 DC volts.
NOTE: If the meter does not read as specified,
replace the sensor.

Speed Sensor

 NOTE: Preliminary checks may be performed on this
component using the diagnostic mode on the LCD
gauge (see EFI Diagnostic System in this section).
NOTE: Prior to testing the speed sensor, inspect the
three-wire connector on the speed sensor for con-
tamination, broken pins, and/or corrosion.
AR603D
1. Set the meter selector to the DC Voltage position.
2. With appropriate needle adapters on the meter leads,
connect the red tester lead to the voltage lead (V); then
connect the black tester lead to the ground lead (G).
PR279A