Conversion Result Read Timing (If Conversion Result Is Normal) - NEC PD789488 User Manual

Pd789489 subseries 8-bit single-chip microcontrollers
Table of Contents

Advertisement

(5)
Timing of undefined A/D conversion result
The A/D conversion value may become undefined if the timing of the completion of A/D conversion and the
timing to stop the A/D conversion operation conflict. Therefore, read the A/D conversion result while the A/D
conversion operation is in progress. To read the A/D conversion result after the A/D conversion operation
has been stopped, stop the A/D conversion operation before the next conversion operation is completed.
Figures 10-8 and 10-9 show the timing at which the conversion result is read.
Figure 10-8. Conversion Result Read Timing (if Conversion Result Is Undefined)
End of A/D conversion
ADCRL0
INTAD0
ADCS0
Normal conversion result is read.
Figure 10-9. Conversion Result Read Timing (if Conversion Result Is Normal)
End of A/D conversion
ADCRL0
INTAD0
ADCS0
CHAPTER 10 10-BIT A/D CONVERTER
End of A/D conversion
Normal conversion result
Normal conversion result
A/D conversion stops.
User's Manual U15331EJ4V1UD
Undefined value
A/D conversion
Undefined value
stops.
is read.
Normal conversion
result is read.
183

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd78f9488Pd78f9489Pd789489

Table of Contents