Operation Of Remote Controller Receiver; Format Of Type A Reception Mode; Operation Flow Of Type A Reception Mode; Example Of Type A Data Format - NEC PD789488 User Manual

Pd789489 subseries 8-bit single-chip microcontrollers
Table of Contents

Advertisement

CHAPTER 15 REMOTE CONTROLLER RECEIVER (

15.4 Operation of Remote Controller Receiver

The following remote controller reception mode is used for this remote controller receiver.
• Type A reception mode with guide pulse (half clock)

15.4.1 Format of type A reception mode

Figure 15-4 shows the data format for type A.
2.4 ms
RIN
Guide pulse
INTRIN
INTGP
INTDFULL
INTREND

15.4.2 Operation flow of type A reception mode

Figure 15-5 shows the operation flow.
Cautions 1. When INTRERR is generated, RMSR and RMSCR are automatically cleared immediately.
2. When data has been set to all the bits of RMSR, the following processing is automatically
performed.
• The value of RMSR is transferred to RMDR.
• INTDFULL is generated.
• RMSR is cleared.
RMDR must then be read before the next data is set to all the bits of RMSR.
3. When INTREND has been generated, read RMSCR first followed by RMSR.
When RMSR has been read, RMSCR and RMSR are automatically cleared.
If INTREND is generated, the next data cannot be received until RMSR is read.
4. RMSR, RMSCR, and RMDR are cleared simultaneously to operation termination (RMEN = 0).
Figure 15-4. Example of Type A Data Format
0.6 ms
1.2 ms
1.8 ms
Data
Data
Data
"0"
"1"
"1"
User's Manual U15331EJ4V1UD
µ
PD789489, 78F9489 ONLY)
Data
Data
Data
Data
"0"
"0"
"0"
"0"
Data
Data
"0"
"0"
RMDLL
RMER
279

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd78f9488Pd78f9489Pd789489

Table of Contents