7. Programming Up/Down Load parameters

ADDRESS 70
Tel No for
Up / Down Load
DEFAULT : No telephone number has been entered
ADDRESS 71
PC ID
DEFAULT : 1234
ADDRESS 72
PANEL ID
DEFAULT : 1234
ADDRESS 73
YES
NO
DEFAULT : NO
ADDRESS 74
NUMBER OF
RINGS
DEFAULT : 7
CA60Plus control panel Installation manual
TELEPHONE NUMBER FOR UP / DOWN LOAD
PROGRAMMING
An up / down load PC telephone number can be set at this address. The indication
is hexadecimal. The maximal length must not exceed 16 characters, including
those for the "pulse dialer" (ON and 0 buttons), "tone dialer" (ON and 1 buttons),
"pause" (ON and 2 buttons), "wait DIAL tone" (ON and 3 buttons) and "delete
telephone number" (ON and 5 buttons) symbols.
Tone signal dialing was assigned by default.
PERSONAL COMPUTER IDENTIFICATION NUMBER FOR UP
/ DOWN LOADING
The PC ID number for up / down loading is configured at this address. Four
digits can be introduced. Valid are symbols 0 to 9.
CONTROL PANEL IDENTIFICATION NUMBER
The control panel up/down loading ID number is entered at this address. Four
digits can be introduced. Valid are symbols 0 to 9.
CALL BACK OPTION
This address enables the CALL BACK option function. Every push of the
digital button alternatively changes enabled to disabled status.
The connection fails if an allowed Call Back function is enabled during an incoming
exchange request to up / down load from a PC. The control panel selects the
number specified at Address 70 and an up / down load procedure is initiated.
The display indication on the keypad is described below.
The Call Back function is enabled. Light-emitting diodes 1 to 6 are lit.
The Call Back function is disabled. Light-emitting diodes 1 to 6 are not lit.
NUMBER OF RINGS
The symbols 0 to 9 are used.
Up/ down loading is disabled if 0 is entered.
It is recommended this parameter does not exceed the value of 7.