Teletek electronics CA60Plus Installation Manual page 18

Hide thumbs Also See for CA60Plus:
Table of Contents

Advertisement

Entry/Exit type
FOLLOW type
INSTANT type
24h Burglar type
FIRE type
PANIC type
18
Provides time to arm and disarm the site. After arming, the sensor, which was
triggered off in this zone, will not sound an alarm until the programmed EXIT
TIME expires.
No violation of the zone when in armed mode will sound an alarm before the
programmed ENTRY TIME expires.
A sound signal is activated from the keyboard buzzer during entry and exit time.
An alarm zone which is active only when the site is armed. The zone operates
instantaneously and activates the programmable ALARM type outputs, the
SIREN output and the communicator.
Activating the zone during entry or exit time does not cause an alarm event.
The MEMORY light-emitting diode and the light-emitting diode for the respective
zone will light up when activated in armed mode. After disarming, these light-emitting
diodes will continue to be lit until the user code is entered or until the next arming.
Where the system is unarmed, the activation of the zone is indicated by the
blinking of the respective light-emitting diode for the zone for the time that the
zone remains open.
An alarm zone which is active only when the site is armed. The zone operates
instantaneously and activates the programmable ALARM type outputs, the
SIREN output and the communicator.
The MEMORY light-emitting diode and the light-emitting diode for the respective
zone will light up when activated in armed mode. After disarming, these light-emitting
diodes will continue to be lit until the user code is entered or until the next arming.
Where the system is unarmed, the activation of the zone is indicated by the
blinking of the respective light-emitting diode for the zone for the time that the
zone remains open.
Violation of INSTANT type zones during Exit Time can be authorized at Address 29.
An alarm zone, which is active, irrespective of the arm mode. The zone operates
instantaneously and activates the programmable ALARM type output, the SIREN
output and the communicator.
The MEMORY light-emitting diode and the light-emitting diode for the respec-
tive zone will light up when activated. After entering a legal code these light-
emitting diodes continue to be lit until the user code is entered a second time or
until the next arming.
Allows connecting 12 V fire alert sensors to the system. These should avail of
a normally closed relay output in inactive status.
Any activation of the zone will trigger off the SIREN output, the programmable
FIRE type outputs and the station communicator.
Activating this zone will cause the MEMORY light-emitting diode to blink and
the activated zone light-emitting diode to light up continuously, irrespective of
the working mode of the station.
The indication of the memory can be deleted by entering a legal user code,
manager code or during the next arming.
Silent Panic – only the programmable PANIC type outputs and the station
communicator can be activated. The respective light-emitting diode blinks while
the zone is active. There is no memory indication. After a legal user code is
entered, the MEMORY light-emitting diode and the activated zone light-emitting
diode both light up continuously.
Sound Panic – the SIREN output, the programmable PANIC type outputs and
the station communicator are activated. The sirens are instantaneously activated
irrespective of the programmed time delay. Activating the zone will cause the
MEMORY light-emitting diode and the activated zone light-emitting diode to
light up continuously.
The indication of the memory can be deleted by entering a legal user code, a
manager code or during the next arming.
Table 1. Types of zones and their attributes
CA60Plus control panel Installation manual