ADDRESS 46
LF DELAY
DEFAULT : 00 minutes
ADDRESS 47
AC DELAY
DEFAULT : NO
ADDRESS 48
ENABLED
DISABLED
DEFAULT : DISABLED
ADDRESS 49
ENABLED
DISABLED
DEFAULT : ENABLED
CA60Plus control panel Installation manual
TELEPHONE LINE FAILURE INDICATION DELAY
A delay of 0 to 99 minutes is set prior to indication of a telephone line failure
(ММ). The indication has a hexadecimal expression. Two digits are entered.
When a period is less than 10 minutes the first digit introduced must be
0. If no indication of a dead telephone line is needed, 00 is entered.
220 V AC POWER SUPPLY FAILURE INDICATION DELAY
NO Disables 30 minutes indication delay for 220 V power supply failure in
keyboards and message transmission via digital communicator.
Light-emitting diodes 1 to 6 do not light up.
YES Enables 30 minutes delay indication for 220 V power supply failure in
keyboards and message transmission via digital communicator.
Light-emitting diodes 1 to 6 light up.
FIRE SIGNAL DURATION
The duration of the alarm signal for a FIRE event is selected at this address.
Programming this address affects the performance of the programmable SIREN
output.
Every click of a digital button alternatively changes the type of duration of the
sound signal. The display indication is shown in the table.
The FIRE signal duration is set at address 42 BELL TIME. The 1 to 6 LEDs
light up.
There is a FIRE alarm signal until a valid system user or master user code is
introduced. The 1 to 6 LEDs do not light up.
TAMPER ALARM SIGNAL
A sound alarm signal is enabled or disabled at this address for a TAMPER
event when the system is not armed. Programming this address will not affect
the TAMPER signal when the system is in armed mode. Programming this
address will affect the performance of the programmable SIREN output.
Every click of a digital button alternatively changes the enabled / disabled
status. The display indication is shown in the table.
Enabled sound alarm signal for TAMPER event, when the system is not armed.
The 1 to 6 LEDs light up.
Disabled sound alarm signal for TAMPER event, when the system is not armed.
A TAMPER event is indicated by an interrupted sound signal emitted by the
system keyboard. The 1 to 6 LEDs do not light up.