Teletek electronics CA60Plus Installation Manual page 25

Hide thumbs Also See for CA60Plus:
Table of Contents

Advertisement

ADDRESS 56
ENABLE
KBD
BLOCK
DEFAULT : NO
ADDRESS 57
1 AC LOST
2 BATT LOW
3 FUSE BLOWN
4 NO TEL LINE
5 COMM ERROR
6 TAMPER
DEFAULT : AC LOST, BATT LOW, FUSE BLOWN, NO TEL LINE, COMM ERROR, TAMPER
CA60Plus control panel Installation manual
ENABLED KEYBOARD BLOCKING IN CASE OF ACCESS
CODE ERROR
NO Disables keyboard blocking in case of access code mistake.
Light-emitting diodes 1 to 6 do not light up.
YES Enables keyboard blocking for 30 sec. following the triple introduction in
sequence of a false code. Light-emitting diodes 1 to 6 light up.
TECHNICAL TROUBLE INDICATION MASK
The mask for sound indication from the keyboard in Technical Trouble mode is
assigned at this address.
The mask for sound indication from the keyboard in Technical Trouble mode is
assigned at this address.
Only those light-emitting diodes whose numbers correspond to technical prob-
lems for which sound indications are available will light up on the display at the
end of the procedure.
Loss of 220 V mains supply.
Drop in battery charge, no battery or burnt out F1 battery fuse.
Burnt out PGM fuse.
Loss of telephone line.
Central station communication failure.
Activated TAMPER within the system.
25