8. Connecting the CA60Plus built-in digital communicator

The telephone line is connected to A and B
terminals on the CA60Plus Control Panel with
no requirements to observe polarity (Fig. 10).
The telephone device is connected to A1 and
B1 terminals on the CA60Plus Control Panel
with no requirements to observe polarity (Fig.
10).
The parameters of the digital communica-
tor are engineer programmed.
It is not necessary to install additional com-
ponents if the built-in communicator is not to be
used.
The system should be powered-up only after it is installed and all necessary devices have been con-
nected – control panel, keyboard, sensors, etc.
In order to set the station to the producer's default parameters place the Reset jumper on the CA60Plus
Control Panel.
Supply 220 V mains power. The keyboard emits a short sound signal and the light-emitting diodes on
the display blink.
Remove the Reset jumper.
Use the red (+) and black (-) cables to connect the battery to the station.
The normal status of the station (all sensors in the security system are inactive and there are no
violated anti-TAMPER chains) is indicated on the keypad by a continuously lit green READY light-
emitting diode. The station has now been programmed the producer default parameters.
All light-emitting diodes will blink and a sound signal will be heard where the keyboard is open or
incorrectly connected.
Where there is an open zone or an open TAMPER for any zone, the light-emitting diode for the
respective zone together with the MEMORY or TAMPER light-emitting diodes on the display will light
up.
NB! An open anti-sabotage chain (TAMPER) in the security system will sound the siren. To
stop the siren key in code 0000. The respective zone light-emitting diode remains perma-
nently lit whereas the TAMPER light-emitting diode will blink. Remove the failure – the
TAMPER light-emitting diode remains permanently lit. Key in code 0000 again to clear the
alarm event from the memory.
Any technical trouble in the panel will light up the Trouble indicator. To view these problems introduce
the 0000 manager code and single-press ENTER. The display will indicate a list of current problems. The
indications and their meaning are shown in Figure 11.
CA60Plus control panel Installation manual

9. Powering the CA60Plus control panel

LED
1
No 220 V power supply
2
Battery low
3
Fuse burned
4
No telephone line
5
No communication available
6
Active TAMPER within the system
Fig. 11 TROUBLE mode indication
A
B
A1
B1
Fig.10 Connecting the CA60Plus
built-in communicator
Technical trouble
}
Telephone line
}
Telephone device