Section 2: Programming; Programming The Software Parameters Of Са62 Alarm Control Panel; The Symbols Used In This Manual; Programming Of Ca62 Via Led Or Lcd Keyboard - Teletek electronics CA62 Installation And Programming Manual

Table of Contents

Advertisement

18
Installation and Programming Manual - СА62 Alarm Control Panel

SeCtIoN 2: PRoGRAMMING

Programming the Software Parameters of СА62 Alarm Control Panel
The system can operate with 4 or 6 digit codes. If a 6 digit code is set at ADDRESS 1001 at the end of every valid code
an extension "00" is automatically added. Next a new 6 digit code combination can be programmed.
The respective parameters can be configured from a LED or LCD keyboard or remotely by means of connected to the
system a personal computer via a telephone using the TTProgramming Suite Software.
Symbols used in this manual
For more clear presentation of the programming with the two types (LED and LCD) keyboards and for easy perform-
ance of the information in this manual, the following symbols for indicating of active (enabled) and inactive (disabled)
parameters in the engineering programming menus are used:
Indicator
ZONES
Keyboard programming
Entering the system engineer code will initiate the CA62 Alarm System programming mode for the engineer param-
eters. After restoring the default parameters (system RESET) the engineer code will remain 7777.
When you enter the engineer programming menu the indication of the used keyboards will be as follows:
- LeD Keyboards - the LEDs RDY (green), ARM (red), TRBL (yellow) and BPS (red) are blinking together. At LED62
keyboard the symbols "lighting", "wrench" and "sheet" are blinking together.
- LCD Keyboards - the LEDs RDY (green), ARM (red) and TRBL (yellow) are blinking together. The
blinks together with symbol
the symbol
is steady.
At LCD type keyboards, after entering engineer programming mode the symbol
clock. Every entered digit of the ADDRESS stop blinking and stays steady, the symbol
ing, which means, that the system is waiting for entering the next digit of the 4 digit ADDRESS.
After entering 4 digit number of a valid ADDRESS a confirmation sound signal will be heard.
After entering of a 4 digit ADDRESS the engineer can program the respective system parameter. Use the provided in
this section tables with detailed descriptions of all available ADDRESSES in the system. You can use also the tables in
SUPPLEMENT A for quick reference. All entered parameters have to be confirmed with pressing the eNt button. When
reviewing the programmed parameters it is recommended to exit any given address by single pressing the CLEAR
button. This function will leave the introduced parameters unchanged. In case the programmer is disoriented in the en-
gineer menu, it is recommended to exit the menu by double clicking the CLEAR button and to begin programming the
station parameters from the start.
AtteNtIoN: the CA62 Alarm System engineer parameters programming mode can be begin only when the
system is in disarmed mode! When there are several (up to 8) keyboards connected to the control panel in
the system you can program parameters only from this one where the engineer code has been entered. the
indication of all other keyboards will show that the system is in engineer programming mode, but you can not
program parameters with them.
How to read the information in the tables below:
ADDRESS
Number
ADDReSS 0001 - HARDWARe ReSet eNABLe
Reset
enable
No
Programming
menu param-
eters
YeS
Default settings
Parameter state
Active (enabled parameter)
Inactive (disabled parameter)
. At LCD63SE keyboard the symbol
Disables or enables the hardware RESET of the alarm station. Specialized service is
required where the hardware ReSet is disabled and the engineer code is obscure.
The parameter status can be changed with pressing of random button of the keyboard.
The hardware RESET is disabled.
The hardware RESET is enabled.
-
YES
LeD
B - Lights on
- Lights off
is blinking, and at the middle tower of the castle
Name of the pro-
gramming menu
Default configuration settings for that programming menu
LCD
(1) - Number enclosed in brackets
1 - Number without brackets
starts blinking at the place of the
next to it will be continue blink-
Description of the pro-
gramming menu
Indication
LeD
     
Indication
LeD
(1) (2) (3) (4) (5) (6)
     
symbol
LCD
1 2 3 4 5 6
LCD

Advertisement

Table of Contents
loading