ADDRESS 90
WALK TEST
ADDRESS 91
LED TEST
ADDRESS 92
OUTPUT TEST
1 PGM1
2 PGM2
3 PGM3
4 SIREN
ADDRESS 93
DISPLAY
COMMUNICATOR The ON button causes test transmission from the communicator to the central
ADDRESS 94
DISPLAY LOG
32

9. CA60Plus test modes

WALK TEST
Enables functional test of station zones. The respective light-emitting diode blinks
while the zone is activated in this mode. As long as there is an open tamper zone
its respective light-emitting diode remains permanently lit.
KEYBOARD TEST
Checks the serviceability of the keypad light-emitting diodes and buzzer.
PGM1, PGM2, PGM3 and SIREN PANEL PROGRAMMABLE
OUTPUT TEST
Serviceability tests of programmable outputs is carried out by pressing a numbered
button which corresponds to the programmable output. The respective light-
emitting diode lights up permanently and the output passes into a low level- 0 V.
Pressing the button with the corresponding number a second time renders the
SIREN output into a high level – 12 V
DISPLAY COMMUNICATOR
The performance of the communicator can be directly monitored at this address.
station and from the voice dialer to
aborts any running communication and deletes the queue of events to be sent.
The CLEAR button exits Address 93. The meaning of the light-emit g diodes is
as follows:
ZONE1:
blinks – searching for a "dial" free tin line / free signal
permanently lit – a "dial" signal has been identified
ZONE2:
blinks – dialing the telephone number
permanently lit – telephone number has been dialed
ZONE3:
blinks – expecting a HAND SHAKE from central station
permanently lit – the necessary handshake signal has been identi-
fied
ZONE4:
blinks – transmitting data to central station
permanently lit – current data has been transmitted
ZONE5:
blinks – expecting confirmation from central station
permanently lit – transmitted data has been successfully received
ZONE6:
permanently lit – communication process has been completed and
all data has been successfully transmitted to the central station
After communication has been successfully completed the keyboard emits a
sound signal.
DISPLAY LOG EVENTS
The events recorded in the power independent memory of the station can be
traced with the help of the arrows. The first event which is visualized is the last
recorded.
assigned telephone numbers