Teletek electronics CA60Plus Installation Manual page 19

Hide thumbs Also See for CA60Plus:
Table of Contents

Advertisement

TAMPER type
MEDICAL type
SWITCH type
AUTOBYPASS attribute
BYPASS attribute
STAY attribute
FORCE attribute
DOUBLE attribute
CHIME attribute
CA60Plus control panel Installation manual
Activating this zone type triggers off the SIREN output, the programmable
TAMPER type outputs and the station communicator. Any activation of the
zone would trigger off a sound signal from the keyboard buzzer where the site
has been disarmed and the TAMPER siren output has been programmed as
SILENT.
The TAMPER light-emitting diode and the light-emitting diode for the respec-
tive activated zone will permanently light up continuously when the zone is
activated. The indication of the memory can be deleted by entering a legal
user code or manager code. A continuously open TAMPER is indicated by a
blinking TAMPER light-emitting diode.
Assigning this zone type will set the programmable MEDICAL type outputs
active and will start the communicator. The activated zone light-emitting diode
will light up irrespective of the system status. The indication of the memory can
be deleted by entering a legal user code, manager code or during the next arming.
Where this zone type is assigned, the respective panel input is used to transmit
the arming and disarming signal with the help of a keyswitch.
Each pulse at the input changes the system arm mode alternatively.
Arming is only possible in Full Arm mode. Arming will be anticipated only
when the system is ready – all zones are inactive.
Assigning this attribute to the respective zone enables automatic bypass in Armed
mode.
The zone will be automatically bypassed following the number of activations
indicated at Address 27 during one single arming.
Any arming will nullify the assigned number of activations of the previous arming.
This attribute is valid for the following zone types: Entry/Exit, Follow,
Instant, 24h Burglar
Assigning this attribute to the respective zone will authorize bypass of the zone
on behalf of the system user or manager.
This attribute is valid for the following zone types: Entry/Exit, Follow,
Instant, 24h Burglar, Fire, Panic, Tamper, Medical, Keyswitch
Assigning this attribute to the respective zone will authorize the respective Stay
mode zone arming.
This attribute is valid for the following zone types: Entry/Exit, Follow,
Instant, 24h Burglar
Assigning this attribute to the respective zone authorizes automatic bypass of
the zone when in Force arm mode.
This attribute is valid for the following zone types: Entry/Exit, Follow,
Instant, 24h Burglar, Fire, Panic, Tamper, Medical
Assigning this attribute to the respective zone authorizes DoubleKnock mode
performance in the zone.
A 3-min. time interval starts when the sensor in the zone is activated for the first
time in armed mode. An alarm event is registered should a second sensor
activation be recorded within this interval in the same or another zone.
An alarm event will also be registered if no zone is restored within 15 seconds
of the first activation of the zone sensor.
This attribute is valid for the following zone types: Entry/Exit, Follow, In-
stant, 24h Burglar
Activating a disarmed zone for which this attribute has been assigned will sound
a specific signal from the keyboards.
This attribute is valid for the following zone types: Entry/Exit, Follow, In-
stant, 24h Burglar, Fire, Panic, Tamper, Medical, Keyswitch
Table 1. Types of zones and their attributes
19