ADDRESS 22
ZONE 2 TYPE AND ATTRIBUTES
DEFAULT : FOLLOW type with BYPASS and STAY attributes
ADDRESS 23
ZONE 3 TYPE AND ATTRIBUTES
DEFAULT : INSTANT type with BYPASS and STAY attributes
ADDRESS 24
ZONE 4 TYPE AND ATTRIBUTES
DEFAULT : INSTANT type with BYPASS and STAY attributes
ADDRESS 25
ZONE 5 TYPE AND ATTRIBUTES
DEFAULT : PANIC type
ADDRESS 26
ZONE 6 TYPE AND ATTRIBUTES
DEFAULT : TAMPER type
ADDRESS 27
NUMBER OF ACTIVATIONS PER ZONE FOR AUTO BYPASS
MODE
DEFAULT : 6
ADDRESS 28
NUMBER OF ACTIVATIONS IN ZONE 4 IN PULSE COUNT
MODE
DEFAULT : 0
ADDRESS 29
ENABLING AND DISABLING FOR INSTANT TYPE ZONES
INSTANT ENABLE NO Disallows intrusion in INSTANT type zones during exit type.
DEFAULT : NO
CA60Plus control panel Installation manual
The programming is the same as for Address 21
The programming is the same as for Address 21
The programming is the same as for Address 21
The programming is the same as for Address 21
The programming is the same as for Address 21.
The number of activations in one arm mode, which have to be accomplished for
a zone with an assigned AUTO/BPS parameter, are entered at this address.
After reaching the indicated number of activations, the respective zone will be
automatically bypassed.
When disarmed and then again armed the respective zone will remain armed.
The number of pulses for zone 4 in Pulse Count mode are entered at this address.
Values of between 0 and 9 pulses can be entered here. The 0 value blocks the
Pulse Count mode and the zone can then function with the regular time for
detecting activation.
The working algorithm for zone 4 in Pulse Count mode has been clarified in
Item 7 on page 8.
Intrusion in any Instant type zone during exit time is allowed or disallowed at
this address. Enabling this working mode would reduce the probability for a
false alarm signal to be triggered off by mistake on behalf of the user.
Light-emitting diodes 1 to 6 do not light up.
YES Allows intrusion in INSTANT type zones during exit type. Light-emitting
diodes 1 to 6 light up.