Special Indication For Reviewing Of Address Number (Led 8 And Led 16A); Programming By Manager; Programming By User - Teletek electronics ECLIPSE 8 User's Operation Manual

Alarm control panels
Hide thumbs Also See for ECLIPSE 8:
Table of Contents

Advertisement

ECLIPSE 8/16/32/99 Series – User Operation Manual

2.6.2 Special indication for reviewing of address number (LED 8 and LED 16A)

With DISARM
manager or user programming.
You can use the button in the following way:
1. The symbols
according the type of the programmed parameter. A blinking digit shows that parameter
which is in setting mode, and lighting on digit button shows the current set value for this
parameter.
2. To find out what is the number of the current ADDRESS, press the
zone numbers 1 and 2 are lighting on, the zone 1 is blinking, and lighting on button shows
the first digit of the address number.
3. Press the right arrow button. The cursor will move one position on the right, zone 2
starts blinking and lighting on digit number shows the next number of the address.
4. Press the
Note: You can also leave the view mode and with single pressing the CANCEL button.
Recommendation: If you are not familiar in details with the programming menus write
down in sequence the digits (of lighting buttons) corresponding to the respective address
positions (zone numbers).

2.6.3 Programming by Manager

• LED 32:
After manager code is entered, a confirmation beep is heard from the keypad. Entrance in
programming mode by a manager is done by pushing the PRG (
lit on the keyboard display, while the "lightning" (white) and "padlock" (red) LEDs flash
only on the keyboard, which is being used for programming. The system expects entrance
of 2-digit code for programming by manager. When a digit button is pushed the
corresponding zone LED lights up. When the "0" button is pushed zone number 10 lights
up.
• LED 8 and LED16A:
After manager code is entered, a confirmation beep is heard from the keypad. Entrance in
programming mode by a manager is done by pushing the PRG (
are lit on the keyboard display and the LEDs
keyboard, which is being used for programming. The system expects entrance of 2-digit
code for programming by manager. The setting of parameters is with pressing the digit
buttons as the button corresponding to the set value is lighting on.

2.6.4 Programming by User

Users in the system do not possess manager rights. Every code with forbidden option 8
Manager (programmed by the manager of the system) is a user code.
• LED 32:
After user code is entered a confirmation beep is heard from the keyboard. Entrance in
programming mode by a user is done by pushing the PRG (
the keyboard display, while the "lightning" (white) and "padlock" (red) LEDs flash only on
the keyboard, which is being used. The system expects entrance of 1-digit programming
address by a user.
button the user can check the number of the current address during
and
are lighting on permanently together with a number of zone(s),
button again to step back in parameter setting mode.
and
are lighting on only at the
10
button. The
) button. Two digits are
) button. Two digits
) button. One digit is lit on

Hide quick links: