F1 BATT
BATTERY
12 V / 7 Ah
Fig. 3
•
AC - power supply from 17 V/24 V A mains transformer
•
Earth – conductor to "EARTH"
•
+AUX and -AUX - 13 V DC power supply to sensors consuming up to 1 А
•
+PGM - 13 V DC power supply to additional devices consuming up to 1 А
•
PGM1, PGM2 and PGM3 – programmable outputs
•
SIREN – siren programmable outputs
•
Z2, Z3, Z4, Z5 and Z6 – zone inputs; ( Z1 zone is at the keyboard)
•
COM – total mass of the zones
•
А and В – connects the telephone line
•
А1 and В1 – connects the telephone device
•
RED and BLACK – keyboard power supply
•
GREEN and YELLOW – interface between the panel and the keyboard
•
F1 - 2 А battery fuse
•
F2 - 1 А fuse for powering sensors, programmable outputs and keyboards
•
F3 - additional device 1 А mains fuse
•
12 V, 7 Ah battery cables
•
RESET – jumper for hardware RESET and default parameter recovery
•
Communicator LED – LED for status indication of built-in digital communicator
•
PROG – terminal for programming by the manufacturer
•
EXPAND – terminal for expander modules (Voice dialer)
6
3. CA60Plus control panel inputs and outputs
F3 AUX
1A
2A
1A
F2 PGM
CA60Plus control panel i
PROG
EXPAND
RESET
nputs and outputs
CA60Plus control panel Installation manual
A
B
A1
B1
Communicator
LED