ADDRESS 60
Tel No 1
DEFAULT : there is no number entered
ADDRESS 61
PANEL ID 1
DEFAULT : 9999
ADDRESS 62
PROTOCOL 1
DEFAULT : 1
ADDRESS 63
Tel No 2
DEFAULT : there is no number entered
ADDRESS 64
PANEL ID 2
DEFAULT : 9999
26

6. Communicator parameters

The parameters of the built-in digital communicator are programmed at this
group of addresses.
Delete the queue of events to be sent to Address 93 by single pressing the 0
button before configuring communicator parameters.
ENTERING TELEPHONE NUMBER 1 FOR THE
COMMUNICATOR
A telephone number is assigned for communicating with central station - No. 1.
The indication is hexadecimal. The telephone number must not exceed 16
characters, including the "pulse dialer" (ON and 0 buttons), "tone dialer" (ON
and 1 buttons), "pause" (ON and 2 buttons), "wait DIAL tone" (ON and 3
buttons) and "delete telephone number" (ON and 5 buttons) symbols.
Dialing has been assigned a default tone signal
ENTERING PANEL IDENTIFICATION NUMBER 1
Identification number for central station No. 1. Four digits are entered. Valid
are symbols 0 to 9, A to F (SIA) and B to F (ADEMCO)
ENTERING PROTOCOL 1 NUMBER FOR THE
COMMUNICATOR
Enter central station No. 1 protocol number from the attached table. Valid are
the symbols from 0 to 2, where:
[0] User protocol – dialer – transmits a melody sound signal upon occurrence of
an event listed on the bottom on page 26
[1] ADEMCO CONTACT ID – see table with codes in Supplement B
[2] SIA (Level 1) - see table with codes in Supplement B
ENTERING TELEPHONE NUMBER 2 FOR THE
COMMUNICATOR
A telephone number is assigned for communicating with central station No. 2.
The indication is hexadecimal. The telephone number must not exceed 16
characters, including the "pulse dialer" (ON and 0 buttons), "tone dialer" (ON
and 1 buttons), "pause" (ON and 2 buttons), "wait DIAL tone" (ON and 3
buttons) and "delete telephone number" (ON and 5 buttons) symbols.
Dialing has been assigned a default tone signal.
ENTERING PANEL IDENTIFICATION NUMBER 2
Identification number for central station No. 2. Four digits are entered. Valid
are symbols 0 to 9, A to F (SIA) and B to F (ADEMCO)
CA60Plus control panel Installation manual