3.6.1 Removin t e Handle
a.
The detector body must first be opened to remove the handle as described in Section
3.1 - Opening the Detector
Disconnect the wiring loom handle. Hold one side of the connector firm against the
•
detector body whilst gently pulling the other side.
Disconnect the spring latch hinge from the latch hinge.
•
Lift the handle off the pin handle pivot.
•
Remove the rod handle slide from the handle.
•
Pass the wiring loom handle through the top of the detector body and lift the handle
•
off the pin handle pivot and away from the detector
b.
The handle has now been removed from the detector and can be replaced if required.
Body. Once completed:
Figure 78: Disconnect Wiring Loom Handle
Rod Handle slide
Figure 79: Handle
Figure 80: Removing Handle and Cable
Pin Handle Pivot
47
F3Ci Service Manual
Handle
Pin Handle Pivot
Spring Latch Hinge
Latch Hinge