Figure 31: Removing the Coil Connector Nut (18mm)
Remove the PCB screw from the main PCB, using a 2.5mm hex key driver.
Disconnect the battery connector from the main PCB.
Figure 32: PCB Screw, Battery Connector and Coil Socket
Slide the coil socket out of the detector body.
Disconnect the Earset cable assembly (internal) from the main PCB. Figure 33.
Disconnect the handle wiring loom from the main PCB.
Disconnect the vibration motor connector from the main PCB.