Fit the PCB screw as shown in Figure 38.
Position the coil connector ensuring the connector has a clean and correctly
positioned O-ring as shown in Figure 39.
Fit coil cable into cable router. Turn the detector over and fit the nut (18mm) to the
Coil Socket.
Figure 37: Fitting Main PCB
O-Ring in place on
Coil Connector
Coil Socket
Figure 39: Coil Connector
27
Figure 38: PCB Screw
Coil Cable Router