F3 COMPACT Service Manual
_______________________________________________________________________________________________________________________
3.6.1 Removing the Handle
a.
The detector body must first be opened to remove the handle as described in Section
3.1 - Opening the Detector
Disconnect the wiring loom handle. Hold one side of the connector firm against the
•
detector body whilst gently pulling the other side. Figure 80.
Disconnect the spring latch hinge from the latch hinge.
•
Lift the handle off the pin handle pivot.
•
Remove the rod handle slide from the handle. Figure 81.
•
Rod Handle slide
Pass the wiring loom handle through the top of the detector. Figure 82.
•
b.
The handle has now been removed from the F3 COMPACT and can be replaced if
required.
Body. Once completed:
Figure 80: Disconnect Wiring Loom Handle
Figure 81: Handle
Figure 82: Removing Handle and Cable
50
Handle
Pin Handle Pivot
Spring Latch Hinge
Latch Hinge
Pin Handle Pivot