Linear Vibration Welder 4000 Series, Model VWA User's Manual
ALARMS
Process Limit
Sensor Valve 1A Extended
Sensor Valve 1B Retracted
Sensor Valve 2A Extended
Sensor Valve 2B Retracted
Sensor Valve 3A Extended
Sensor Valve 3B Retracted
Alarms and Messages (Page 4 of 6)
Table 6-II
Page 88
MESSAGE
One of the "actual"readings is not within your process limits.
[Valve 1A] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 1B] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 2A] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 2B] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 3A] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 3B] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
Dukane Manual Part No. 403-592-00