ALARMS
Sensor Valve 4A Extended
Sensor Valve 4B Retracted
Sensor Valve 5A Extended
Sensor Valve 5B Retracted
Sensor Valve 6A Extended
Sensor Valve 6B Retracted
Alarms and Messages (Page 5 of 6)
Table 6-II
Dukane Manual Part No. 403-592-00
MESSAGE
[Valve 4A] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 4B] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 5A] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 5B] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 6A] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
[Valve 6B] has been triggered, but sensor was not acknowledged.
Solutions:
Check that actuated device is not obstructed.
Check the air pressure setting on the valve.
Check sensor position; make adjustment if necessary.
Section 6 - Touch Screen Menus
Page 89