K AC Utility Outlet
An AC utility outlet is provided on the front control panel
(see Figure 4-2). The duplex outlet is a standard feature
and has snap–close covers. For machines intended for use
in North America, the outlets are rated at 4 Amps total at
120 Volts AC.
For machines configured for use outside North America,
the outlets are wired for the voltage appropriate for use in
the intended country of installation. The 4 Amp rating is
the maximum combined current that should be drawn from
the outlets. The utility outlet has its own circuit breaker in
the electrical cabinet. Refer to Figure 10-2 for the location
of the AC outlet breaker inside the electrical cabinet.
L Vacuum On/Off Button
Vacuum holds parts in place on the upper tool.
This button allows the operator to control the vacuum
manually.
Pressing the button turns the vacuum on or off.
This is typically used when setting up the machine, and
when making adjustments to part placement.
See Page 69 for more information.
Dukane Manual Part No. 403-592-00
Power
LED
Right Operate Switch and Vacuum Button
Figure 4- 5
Vacuum must be turned on before the
Vacuum ON/Off Button will work.
Section 4 - Display and Controls
Activated
LED
Vacuum
ON/OFF
NOTE
Page 31