Reset Part Counter
Reset Susp. Part
Counter
Tool Weight
Compensation
This feature allows the operator to make an adjustment for
the weight of the tool and table. The adjustment is called
the offset.
System Force - The force of the hydraulic system
at any given moment is System Force. During Tool
Weight Compensation, the pressure begins at idle
pressure. It builds until enough force is available
to move the table and the lower tool.
Offset Force - The
force required to move
the lift table and the
lower tool.
Figure 6-28 Tool Weight Compensation Pop-up Window
Dukane Manual Part No. 403-592-00
Touch this button to reset
the part counter.
Touch this button to reset the
suspect part counter.
Touch this button to open the
Tool Weight Compensation
pop-up window.
Reset Offset - Touch
this button to reset the
tool weight offset.
Section 6 - Touch Screen Menus
Indicator lights up to show
when tool weight sampling
is in progress .
Capture Offset - Touch
this button to start the
tool weight compensa-
tion process.