Gigaset 1054isdn User Instructions page 32

Table of Contents

Advertisement

10.06.1999
Installation
Connection Examples for Intercoms Using TFE
The following example shows how different types of door intercoms can be connected to
Gigaset 1054isdn using the Siemens door intercom adapter (TFE/V).
Grothe
TS 6216
L
O
B
U
Back view
Gigaset 1054isdn
Recommended:
Possible back-
ground noise
can be eliminated
with the following
switching.
Considerations with the Door Intercom Adapter (TFE/V):
– The potentiometer should be set to the maximum volume (all the way to the right).
– The bridge X1 cannot be changed.
– Adjustment for bridge X2:
For the individual door stations the following different changes must be taken into con-
sideration:
Door station
SIEDLE TLM 511/01
RITTO 5760
Grothe
28
1054I-02.FM
RITTO
Siedle
Siedle
5760
TLM 511
TLM 051
2
12
+
13
+
14
11
6
Door bell transformer
8 - 12 V
220 V
Door opener function not possible
Door Bell
connection cable
1000uF
40V/1A
SIEDLE TLM 511
Changes in the door station
- Bridge 1, 3, 4 open.
- Replug wire from loudspeaker from "bl" pin to "12" .
- No change
- Reclamp the yellow wire from "B" to "0" .
Gigaset 1054 isdn, GBR: A30853-X200-B101-51-7619
Non-Cordless Devices
TFE/V S30817-K936-A313
12
LS1
+
LS2
14
MIC+
MIC-
11
AC
AC
TOE
TOE
KLI
KLI
B
A
AC
20V
AC
RITTO 5760
Bridge X1
Potentiometer
Bridge X2
Grothe TS 6216

Advertisement

Table of Contents
loading

Table of Contents