ST004
/
No continuity
ST0201
0
Field Frame (Field Coil)
1.
INSPECT FIELD COIL FOR OPEN CIRCUIT
Using an ohmmeter,
check that there
is continuity
be-
tween the lead wire and field coil brush lead.
If there is no continuity,
replace the field frame.
2.
INSPECT THAT FIELD COIL IS NOT GROUNDED
Using an ohmmeter,
check that there is no continuity
be-
tween the field coil end and field frame.
If there is continuity,
repair or replace the field frame.
Brushes
INSPECT
BRUSH LENGTH
Using vernier calipers, measure
the brush length.
Standard
length:
1 .O kW type
13.5 mm (0.531
in.)
1.4 kW type
15.5 mm (0.610
in.)
Minimum
length:
1.0 kW type
8.5 mm (0.335
in.)
1.4 kW type
10.0 mm (0.394
in.)
If the length
is less than
minimum,
replace
the brush
holder and field frame.