Important Notice For Machine - Ricoh D146 Service Manual

Hide thumbs Also See for D146:
Table of Contents

Advertisement

Guidance for Those Who are Familiar with Predecessor Products

1.4.3 IMPORTANT NOTICE FOR MACHINE

Item
SP cord
Procedure at electrical
board replacement
VM function on CTL
board
Grease used in fusing
unit
Release way for
Fusing high
temperature detection
SRA3 option
(Imageable Area
Extension Unit Type
M3)
D146/D147/D148/D149/D150
D146/D147/D148/D149/D150
SP enter code change
To hold the main switch down is
always required before start
procedure for electrical board
replacement.
(discharge of remaining charge)
VM function built in CTL board.
Accordingly, the procedure to
update VM firmware is changed.
Metal use purpose grease
(Fluotribo) on pressure roller and
bushing.
Fusing unit replacement is
required only at SC544/554
(Fusing high temperature
detection) occurrence.
§
SP setting is required at the
option installation.
§
This have PM yield as well as
normal PTR. Regular PM
replacement is required.
1-44
Predecessor
-
No procedure
VM function is provided by
SD card option.
Traditional grease
(Barrierta)
Fusing unit replacement is
required at
SC544/554/564/574
occurrence.
-
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D147D149D148D150

Table of Contents