Connection example in cooling mode

PCU
S AMB B
S AMB A
2 1
2 1
S DEP B
2 1
2 1
4
10
15
A/B
A
B
Not used: Do not connect anything to the terminal block.
A
Z
CAUTION
Do not connect anything to the DHW pump
outlet as the reversal valve is connected to the
PCU PCB in the boiler.
Connect the outside temperature sensor.
E
Connect the 3-way valve motor (circuit B) and the circuit
R
B flow sensor.
Connect the heating pump (Circuit B).
T
Connect a safety thermostat if the heating circuit is for
Y
underfloor heating: Remove the bridge. Connect the wires
from the safety thermostat to the connector.
Connect the DHW sensor.
U