Connection Example In Power Cut Off Evu - DeDietrich AWHP-2 MIT-IN-2 iSystem Installation And Service Manual

Hide thumbs Also See for AWHP-2 MIT-IN-2 iSystem:
Table of Contents

Advertisement

AWHP-2 MIT-IN-2 iSystem
B
TS +
1
2
4
5 6
14
BUS
12
25/06/2014 - 7616371-001-04
SCU
0-10V
S AMB C
+ -
4 3 2 1 2 1
B
A
S SYST + TA -
S ECS
S EXT S DEP C
2 1
2 1
2 1
2 1
11
8
7
3
3
EVU
A/B
A
B
4.11.19.

Connection example in power cut off EVU

PCU
S AMB B
S AMB A
2 1
2 1
S DEP B
2 1
2 1
4
10
13
A/B
A
B
15
Not used: Do not connect anything to the terminal block.
A
Z
CAUTION
Do not connect anything to the DHW pump
outlet as the reversal valve is connected to the
PCU PCB in the boiler.
Connect the outside temperature sensor.
E
Connect the 3-way valve motor (circuit B) and the circuit
R
B flow sensor.
Connect the heating pump (Circuit B).
T
Connect a safety thermostat if the heating circuit is for
Y
underfloor heating: Remove the bridge. Connect the wires
from the safety thermostat to the connector.
Connect the DHW sensor (Package AD212).
U
4. Installation
9
M003037-B