ALEZIO S V200
User Guide
Reversible air/water "Split Inverter" heat pump
ALEZIO S V200
MIV-4S/E 4-8 V200
MIV-4S/E 11-16 V200
MIV-4S/H 4-8 V200
MIV-4S/H 11-16 V200
S U S T A I N A B L E C O M F O R T ®

Advertisement

Table of Contents
loading

Summary of Contents for DeDietrich ALEZIO S V200

  • Page 1 EASYLIFE ALEZIO S V200 User Guide Reversible air/water "Split Inverter" heat pump ALEZIO S V200 MIV-4S/E 4-8 V200 MIV-4S/E 11-16 V200 MIV-4S/H 4-8 V200 MIV-4S/H 11-16 V200 S U S T A I N A B L E C O M F O R T ®...
  • Page 2 Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer service organisation can assist with this.
  • Page 3: Table Of Contents

    Contents Contents Safety instructions and recommendations ..............5 Safety .
  • Page 4 Contents Check the hydraulic pressure ..............27 Cleaning the casing .
  • Page 5: Safety Instructions And Recommendations

    1 Safety instructions and recommendations Safety instructions and recommendations Safety Operation Danger This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the haz­...
  • Page 6: General Instructions

    1 Safety instructions and recommendations Domestic wa­ Draining the appliance: 1. Shut off the domestic cold water inlet. 2. Open a hot water tap in the installation. 3. Open a valve on the safety unit. 4. To drain, open the tap at the base of the tank. The pressure limiter device (safety valve or safety unit) must be regularly oper­...
  • Page 7: Refrigerant Safety

    1 Safety instructions and recommendations Refrigerant safety Warning Refrigerant fluid and pipes: Use only R410A refrigerant fluid to fill the installation. Use tools and pipe components especially designed for use with R410A refrigerant fluid. Use copper pipes deoxidised with phosphorus to carry the refrigerant fluid.
  • Page 8: Hydraulic Safety

    1 Safety instructions and recommendations Hydraulic safety When making the hydraulic connection, it is imperative that the standards and corresponding local directives be respected. If radiators are connected directly to the heating circuit: install a differential valve between the indoor module and the heating circuit. Fit drainage valves between the indoor module and the heating circuit.
  • Page 9: Liabilities

    1 Safety instructions and recommendations Remove the casing only to perform maintenance and repair work. Put the casing back in place after maintenance and repair work. The user must make sure the refrigerant pipes are checked annually for leaks for any heat pump with a charge greater than 5 tonnes of CO equivalent.
  • Page 10: Symbols Used

    2 Symbols used Symbols used Symbols used in the manual This manual uses various danger levels to draw attention to special instructions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance. Danger Risk of dangerous situations that may result in serious personal injury.
  • Page 11 2 Symbols used Fig.2 Symbols used on the connection 1 Sensor cable - low voltage label 2 Power supply cable 230 V / 400 V 3 Heating circuit flow 4 Circuit B flow 5 Heating circuit return 6 Circuit B return (optional) G1"...
  • Page 12: Technical Specifications

    3 Technical specifications Technical specifications Homologations 3.1.1 Directives This product complies with the requirements of the following European Directives and Standards: Pressure Equipment Directive 2014/68/EU Low Voltage Directive 2014/35/EU Generic standard: EN 60335-1 Relevant standards: EN 60335-2-21, EN 60335-2-40 Electromagnetic Compatibility Directive 2014/30/EU Generic standards: EN 61000-6-3, EN 61000-6-1 Relevant Standard: EN 55014 This product conforms to the requirements of European Directive...
  • Page 13 3 Technical specifications Tab.2 Heating mode: outside air temperature +7 °C, water temperature at the outlet +35 °C. Performances in accordance with EN 14511-2. Measurement type Unit AWHP 4.5 AWHP 6 AWHP 8 AWHP 11 AWHP 11 AWHP 16 AWHP 16 MR-3 MR-2 MR-2...
  • Page 14: Heat Pump Weight

    3 Technical specifications 3.2.2 Heat pump weight Tab.6 Indoor module Indoor module Unit MIV-4S/E 4-8 V200 MIV-4S/H 4-8 V200 MIV-4S/E 11-16 MIV-4S/H 11-16 V200 V200 Weight (empty) Total weight with water Tab.7 Outdoor unit Outdoor unit Unit AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2 AWHP 11 MR-2...
  • Page 15: Combination Heaters With Medium-Temperature Heat Pump

    3 Technical specifications 3.2.4 Combination heaters with medium-temperature heat pump Tab.11 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application) Product name MIV-4S V200 MIV-4S V200 MIV-4S V200 AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2 Air-to-water heat pump Water-to-water heat pump Brine-to-water heat pump...
  • Page 16 3 Technical specifications Product name MIV-4S V200 MIV-4S V200 MIV-4S V200 AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2 Capacity control Variable Variable Variable Sound power level, indoors - outdoors 49 – 61 49 – 62 49 – 67 Annual energy consumption under average con­...
  • Page 17: Circulating Pump

    3 Technical specifications Product name MIV-4S V200 MIV-4S V200 AWHP 11 MR-2 AWHP 16 MR-2 AWHP 11 TR-2 AWHP 16 TR-2 = -7°C COPd 1.87 1.85 COPd = +2°C 3.17 3.02 COPd = +7°C 4.54 4.34 COPd = +12°C 6.19 5.75 COPd = bivalent temperature...
  • Page 18: Description Of The Product

    4 Description of the product Description of the product Main components Fig.3 Main components 1 Control panel access flap 2 User interface 3 ON/OFF button MW-3000471-2 Operating principle The outdoor unit produces heat or cold and transfers it to the indoor module via the refrigerant in the plate exchanger.
  • Page 19: Operation

    5 Operation Operation Control panel description 5.1.1 Description of the user interface Fig.4 1 Rotary knob to select a menu or setting 2 Validation button 3 Back key to return to the previous level or previous menu 4 Main menu key 5 Display screen 6 LED for status indication: continuous green = normal operation...
  • Page 20: Starting And Stopping The Heat Pump

    5 Operation Starting and stopping the heat pump 5.2.1 Starting the heat pump 1. Switch on the outdoor unit and the indoor module. The message "Welcome" will appear on the screen. The heat pump begins its start-up cycle. 2. If an error message is displayed on the home screen, contact the installer.
  • Page 21: Personalising The Zones

    5 Operation 3. Carry out one of the following operations: Tab.15 Menu Description Set Date and Time Setting the date and time Select Country and Language Select the country and language. Setting the automatic change to daylight saving time. These changes will be carried out on the Daylight Saving Time last Sunday in March and October Installer Details...
  • Page 22: Changing The Name Of An Activity

    5 Operation Fig.7 °C Tab.17 Example: Start Activity Set point temperature of the activity 6:30 20 °C Morning 9:00 19 °C Away 06:30 09:00 17:00 20:00 23:00 17:00 20 °C Home MW-1001144-2 20:00 22 °C Evening 23:00 16 °C Sleep 5.7.2 Changing the name of an activity The name of the different activities is factory-set: Sleep, Home, Away,...
  • Page 23: Activating And Configuring A Timer Programme For Heating

    5 Operation 2. Select the desired operating mode: Tab.18 Mode Description The room temperature is modulated according to the timer programme chosen. Scheduling Recommended mode. The room temperature is constant. Manual The room temperature is forced for a defined period. Short temperature change The room temperature is reduced during an absence period to save energy.
  • Page 24: Changing The Room Temperature Temporarily

    5 Operation Fig.9 2. To modify the timer programme for the Cooling mode, select Zone configuration > Cooling Schedule. 14 : 23 Zo.. Zone setup: ... Cooling Schedule The programmed activities for Sunday are displayed. Sunday The last activity of the day remains active until the first activity of the 14:00 Comfort 24.0°C...
  • Page 25: Forcing Domestic Hot Water Production (Override)

    5 Operation 3. Select the timer programme to be activated. Information on the active timer programme is given in the upper part of the screen. Fig.10 4. To modify the timer programme, select Zone configuration > DHW Schedule. 14 : 23 Zo...
  • Page 26: Maintenance

    6 Maintenance Maintenance General Maintenance operations are important for the following reasons: To guarantee optimum performance. To extend the life of the equipment. To provide an installation which offers the user optimum comfort over time. Caution Only qualified professionals are authorised to carry out maintenance work on the heat pump and the heating system.
  • Page 27: Check The Hydraulic Pressure

    6 Maintenance 2. Consult the information linked to the maintenance and servicing of your appliance: Information Description Maintenance required Indicates the necessity of mainte­ nance: yes/no Current maintenance Type of maintenance to come Service run hours Number of hours that the appliance has been producing energy since last service Hours since service...
  • Page 28: Troubleshooting

    7 Troubleshooting Troubleshooting Resolving operating errors If your appliance malfunctions, the status LED flashes and/or changes colour and a message containing an error code is displayed on the main screen of the control panel. This error code is important for the correct and rapid diagnosis of the type of malfunction and for any technical assistance that may be needed.
  • Page 29 7 Troubleshooting Problems Probable causes Corrections The heat pump does The heating set point tem­ Increase the value of the room temperature set point or, if a room ther­ not work. perature is too low. mostat is connected, increase the temperature on it. The heat pump is not op­...
  • Page 30: Decommissioning And Disposal

    8 Decommissioning and disposal Decommissioning and disposal Decommissioning procedure To decommission the heat pump temporarily or permanently: 1. Contact the installer. Disposal and recycling Fig.11 Warning Removal and disposal of the heat pump must be carried out by a qualified professional in accordance with prevailing local and national regulations.
  • Page 31: Energy Savings

    9 Energy savings Energy savings Energy-saving advice: Do not block ventilation outlets. Do not cover the radiators. Do not hang curtains in front of the radiators. Install reflective panels behind the radiators to prevent heat losses. Insulate the pipes in rooms that are not heated (cellars and lofts). Close the radiators in rooms not in use.
  • Page 32: 10 Product Fiche And Package Fiche

    10 Product fiche and package fiche 10 Product fiche and package fiche 10.1 Product fiche Tab.21 Product data sheet for heat pump combination heaters MIV-4S V200 MIV-4S V200 MIV-4S V200 AWHP 4.5 AWHP 6 MR-3 AWHP 8 MR-2 Space heating - Temperature application Medium Medium Medium...
  • Page 33: Product Fiche - Temperature Controls

    10 Product fiche and package fiche MIV-4S V200 MIV-4S V200 AWHP 11 MR-2 AWHP 16 MR-2 AWHP 11 TR-2 AWHP 16 TR-2 Seasonal space heating energy efficiency under average climate condi­ tions Water heating energy efficiency under average climate conditions 106,00 106,00 Sound power level L...
  • Page 34 10 Product fiche and package fiche Fig.12 Package fiche for medium-temperature heat pumps indicating the space heating energy efficiency of the package Seasonal space heating energy effi ciency of heat pump ‘I’ Temperature control Class I = 1%, Class II = 2%, Class III = 1.5%, Class IV = 2%, Class V = 3%, Class VI = 4%, from fi...
  • Page 35 10 Product fiche and package fiche Tab.24 Weighting of medium temperature heat pumps II, package without hot water storage tank II, package with hot water storage tank Prated / (Prated + Psup) (1)(2) 1.00 1.00 0.70 0.63 0.45 0.30 0.25 0.15 0.15 0.06...
  • Page 36: Package Fiche - Combination Heaters (Boilers Or Heat Pumps)

    10 Product fiche and package fiche 10.4 Package fiche - Combination heaters (boilers or heat pumps) Fig.13 Package fiche for combination heaters (boilers or heat pumps) indicating the water heating energy efficiency of the package Water heating energy effi ciency of combination heater ‘I’...
  • Page 37: 11 Appendix

    11 Appendix 11 Appendix 11.1 Name and symbol of the zones Tab.26 Factory-set name Factory-set sym­ Customer-set name and symbol CIRCA CIRCB 11.2 Name and temperature of the activities Tab.27 Name and temperature of the activities for heating Factory-set name Factory-set tempera­...
  • Page 38 11 Appendix MIV-4S V200 7682822 - v03 - 27082018...
  • Page 39 © Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations.