AWHP-2 MIT-IN-2 iSystem
User level - Menu #SETTING
Parameter
SUM/WIN
CALIBR.OUT
(1)
CALIBR.ROOM A
(2)
OFFSET ROOM A
ANTIFR.ROOM A
(1)
CALIBR.ROOM B
(3)
(2)
OFFSET ROOM B
(3)
(3)
ANTIFR.ROOM B
(1)
CALIBR.ROOM C
(3)
(2)
OFFSET ROOM C
(3)
(3)
ANTIFR.ROOM C
(4)
COST HIGH TARIFF
(4)
COST HIGH TARIFF
(4)
COST GAS.OIL
(1) The parameter is only displayed if a room sensor is connected to the circuit concerned
(2) The parameter is only displayed if no room sensor is connected to the circuit concerned or the sensor has no influence
(3) The parameter is only displayed if the circuit concerned is actually connected
(4) The parameter is only displayed if HYBRID ENABLED is set to COST
25/06/2014 - 7616371-001-04
Adjustment
Description
range
15 to 30 °C
Used to set the outside temperature above
which heating will be shut down.
The heating pumps are shut down.
4
The heat pump only starts up for
4
domestic hot water needs.
In this case the letter E and symbol p
4
are displayed.
Heating is never shut down automatically
NO
Outside sensor calibration: Used to correct
the outside temperature
Calibration of the room sensor on circuit A
Make this setting 2 hours after switching on,
when the room temperature has stabilised
-5.0 to +5.0 °C
Room offset on circuit A: Is used to set a
room offset
Make this setting 2 hours after switching on,
when the room temperature has stabilised
0.5 to 20 °C
Room temperature antifreeze activation on
circuit A
Calibration of the room sensor on circuit B
Make this setting 2 hours after switching on,
when the room temperature has stabilised
-5.0 to +5.0 °C
Room offset on circuit B: Is used to set a
room offset
Make this setting 2 hours after switching on,
when the room temperature has stabilised
0.5 to 20 °C
Room temperature at which the antifreeze
mode is activated on circuit B
Calibration of the room sensor on circuit C
Make this setting 2 hours after switching on,
when the room temperature has stabilised
-5.0 to +5.0 °C
Room offset on circuit C: Is used to set a
room offset
Make this setting 2 hours after switching on,
when the room temperature has stabilised
0.5 to 20 °C
Room temperature antifreeze activation on
circuit C
€ 0.01 to € 2.50
Cost of peak time electrical energy.
€ 0.01 to € 2.50
Cost of off-peak electrical energy. The tariff
is only factored in if parameter E. BL is set
to HP/HC and the contact on the BL input is
closed.
¼ "Professional settings", page
98
€ 0.01 to € 2.50
Cost of fossil energy (oil or gas). (Price per
litre or m
3
)
5. Commissioning
Factory setting
Customer
setting
22 °C
Outside
temperature
Room
temperature of
circuit A
0.0
6 °C
Room
temperature of
circuit B
0.0
6 °C
Room
temperature of
circuit C
0.0
6 °C
0.13
0.09
0.90
97