8. Troubleshooting
After Sales level - Menu #INFORMATION
Parameter
S/N SCU
CTRL
VER.ROM PCU
VERS.PARAM PCU
(1)
MC.VERSION
(1)
NUMBER REMOT A
(1)
NUMBER REMOT B
(1)
NUMBER REMOT C
(1)
VERS.SUN
CALIBRA.CLOCK
(1) The parameter is only displayed for the options, circuits or sensors actually connected
After Sales level - Menu #METERS
Parameter
NB IMPULS.COMP
RUNTIME HP
FCT.HYDRO
NB IMPULS.HYDRO
FCT. STAGE 1
NB IMP.STAGE 1
FCT.STAGE 2
NB IMP.STAGE 2
FCT. APP.DHW
(1)
ELEC.ENERGY HEAT
(1)
ELEC.EN.DHW
(1)
ELEC.ENERGY COOL
(1)
ELEC.ENERGY
(1)
ELEC.ENERG.Y1
(1)
ELEC.ENERG.Y2
THERM.ENERG.HEAT
(1)
(1)
THERM.ENERG.DHW
THERM.ENERG.COOL
(1)
(1)
THERM.ENERGY
(1)
THERM.ENERG.Y1
(1)
THERM.ENERG.Y2
(1)
PERF.FACTOR
(1)
PERF.FACTOR A1
(1) The parameter is only displayed if the corresponding option is connected
Control system sequence
Status
0
Stop
128
Description
Serial number of the SCU board
Software control number
Version of the PCU PCB programme
Version of the PCU PCB parameters
Version of the boiler radio module programme
Information
Information
Information
Solar control system software version
Clock calibration
Description
Number of heat pump start-ups
Number of hours' operation of compressor
Number of hours operation of the hydraulic backup
Number of start-ups of the hydraulic backup
Number of hours' back-up operation stage 1
Number of back-up starts stage 1
Number of hours' back-up operation stage 2
Number of back-up starts stage 2
Number of hours' operation of the back-ups
Consumption of electrical energy in heating mode
Consumption of electrical energy in DHW mode
Consumption of electrical energy in cooling mode
Total electrical energy consumed
Total electrical energy consumed in the previous year
Total electrical energy consumed two years ago
Thermal energy generated in heating mode
Thermal energy generated in DHW mode
Thermal energy generated in cooling mode
Total thermal energy yield
Total thermal energy yield in the previous year
Total thermal energy yield two years ago
Seasonal coefficient of performance
Seasonal coefficient of performance the previous year
Sub-status
0
Stop
10 Time delay on reversibility
AWHP-2 MIT-IN-2 iSystem
Heating Domestic hot
water
x
x
x
25/06/2014 - 7616371-001-04
Remarks
Total shutdown