n SCREED DRYING
Used to force a constant flow temperature or a train to accelerate
screed drying on underfloor heating.
The setting for these temperatures must follow the screed-layer's
recommendations.
The activation of this parameter (setting other than OFF) forces the
permanent display of SCREED DRYINGE CHAPE} and deactivates
all other functions on the control unit.
When floor drying is active on a circuit, all other circuits (e.g. DHW)
are shut down. The use of this function is only possible on circuits B
and C.
STOP DRYING TEMP
A
START DRYING TEMP
Z
Today
E
NB DAYS DRYING
R
Normal regulation (End of drying)
T
Heating temperature setting (°C)
Y
For example
A
STOP DRYING TEMP: 47 °C
Z
START DRYING TEMP: 20 °C
NB DAYS DRYING
R
Normal regulation (End of drying)
T
Heating temperature setting (°C)
Y
Every day at midnight (00:00): the set point (START
DRYING TEMP) is recalculated and the remaining number
of days (NB DAYS DRYING) is decremented.
n ROOM S.INFL
Used to adjust the influence of the room sensor on the water
temperature for the circuit concerned.
Adjustment Description
No influence (remote control fitted in a location with no
0
influence)
Slight influence
1
Average influence (recommended)
3
Room thermostat type operation
10