Sensor Characteristics - DeDietrich AWHP-2 MIT-IN-2 iSystem Installation And Service Manual

Hide thumbs Also See for AWHP-2 MIT-IN-2 iSystem:
Table of Contents

Advertisement

3. Technical description
AWHP
dB(A) 41.7
(1)
Sound pressure
Nominal water flow
3
m
(ΔT = 5K)
Manometric height
mbar
available at nominal
flow rate
Nominal air flow rate m
3
Power voltage of the
V
outdoor unit
(2)
dB(A) 63.7
Sound output
R410A refrigerant
kg
refrigerant piping
inch
connection (Liquid-
Gas)
Max pre-loaded
m
length
Weight (empty) -
kg
Outside unit
(1) 5 m from the appliance, free field.
(2) Test conducted in accordance with the standard NF EN 12102
Outside sensor
Temperature in °C -20
Resistance in Ω
2392 2088 1811 1562 1342 1149 984 842 720 616 528 454
DHW sensor
Flow sensor
Temperature in °C 0
Resistance in Ω
32014 19691 12474 10000 8080 5372 3661 2535 1794 1290 941
16
4 MR
6 MR -2 8 MR-2 11 MR-2 11 TR-2 16 MR-2 16 TR-2 22 TR
41.7
43.2
1.04
1.04
1.47
/h
618
618
493
2100
2100
3000
/h
230 V~ 230 V~
230 V~ 230 V~
63.7
65.2
2.1
2.1
3.2
1/4-1/2 1/4-1/2
3/8-5/8 3/8-5/8
10
10
10
42
42
75
-16
-12
-8
-4
10
20
25
n General values
43.4
43.4
1.88
1.88
393
393
6000
6000
400 V3~ 230 V~
65.4
65.4
4.6
4.6
3/8-5/8
10
10
118
118
3.4.3.

Sensor characteristics

0
4
8
12
30
40
50
60
AWHP-2 MIT-IN-2 iSystem
47.4
47.4
51.8
2.67
2.67
3.8
213
213
-
6000
6000
8400
400 V3~ 400 V3~
69.4
69.4
73.8
4.6
4.6
7.1
3/8-5/8
3/8-5/8
3/8-3/4 or
3/8-1
10
10
30
130
130
135
16
20
24
70
80
90
25/06/2014 - 7616371-001-04
27 TR
53
4.6
-
8400
400 V3~
75
7.7
1/2-3/4 or
1/2-1
30
141

Hide quick links: